TM 10-4320-351-14
a.
Removal.
WARNING
Rubber gloves should be worn when handling fueling system components due to
the toxic effects of some fuel additives.
(1)
Remove ball retaining screw (1) and 0-ring (2). Discard O-ring (2).
(2)
Position a wiping rag under coupling (3) and orient coupling (3) screw hole toward wiping rag. Push in and
rotate unisex coupling (3) back and forth until all 41 balls (4) have collected in the wiping rag.
(3)
Pull unisex coupling (3) from inlet (5).
(4)
Remove and discard outside O-ring (6) from inlet (5).
(5)
Remove and discard nylon seal (7) and inside O-ring (8) from inlet (5).
(6)
Remove and retain eight springs (9).
Figure 4-6. Inlet Manifold Unisex Coupling Replacement
4-17
|