TM 10-4320-351-14
INITIAL SETUP FOR PUMPING ASSEMBLY LUBRICATION (ENGINE OIL CHANGE)
Tools
Materials/Parts
Pan, Drain (Appendix B, Section III, Item 1)
Rags, Wiping (Appendix F, Section II, Item 4)
Wrench, Oil Filter (Appendix B, Section III, Item 1)
Personnel Required
Four, any MOS
Table 4-1. Unit Preventive Maintenance Checks and Services for Pumping Assembly
Location
Procedure
Not Fully Mission
Item
Interval
Item to
Capable if:
No.
Check/
Service
1
Weekly
Pump Overtemp
Perform electrical circuit test. Refer to paragraph 4.9.2.c(a).
Switch fails test
Switch
2
Annually
Pump Overtemp Perform test of the thermostat over-temperature sensor.
Sensor is open
Sensor
Refer to paragraph 4.9.2. c (b).
WARNING
Fuel fumes are always present in the
vicinity of the pumping assembly. Death
or personal injury may result from the
explosion of fuel fumes exposed to an
open flame or spark. Do not permit
smoking, any open flame, or spark
producing equipment within 50 feet (15
m) of the pumping assembly.
3
200
Engine
Perform engine oil change.
Oil level is above
hours
MAX or below MIN
Oil filters shall be serviced/cleaned/changed as applicable,
mark on dipstick.
when:
a. They are known to be contaminated or clogged.
b. Service is recommended by AOAP laboratory
analysis.
c. At prescribed hardtime intervals.
This pumping assembly is not enrolled in the Army Oil
Analysis Program. HARDTIME INTERVALS APPLY.
a. Remove engine module from pump-engine module (Refer to
paragraph 2.4.b) and place engine module high enough to
allow oil drain pan to fit beneath oil drain plug.
b. Remove oil filler cap next to dipstick.
c. Place oil drain pan beneath oil drain plug, remove the drain
plug and drain the oil. Dispose of in accordance with local
SOP.
d. Remove the oil filter, taking care not to spill oil from filter.
Dispose of in accordance with local SOP.
4-5
|