Page Title: Table 2-3. Operator's Preventive Maintenance Checks and Services for Pumping Assembly
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 10-4320-351-14 Table 2-3.  Operator's Preventive Maintenance Checks and Services for Pumping Assembly Location Procedure Not Fully Mission Item Interval Item to Capable if: No. Check/ Service 2 Before Air Filter Check condition of air filter element (1).  Remove element and tap lightly against hand to remove clogging.  Replace element if required.  Verify that dust ejector (2) points down when cover (3) is installed.  Check condition of hose (4) and tightness of hose clamps (5). 3 Before Pump-Engine Inspect ground cable for cuts, breaks or loose connections. Cuts, breaks or loose Module connections make Ground ground cable unusable. Cable 4 B Pump-Engine Inspect fuel and oil lines for cuts, breaks or loose connections. Fuel or oil lines are cut, Module Fuel broken or have loose and Oil connections. Lines 2-7