TM 10-4320-351-14
Table 2-3. Operator's Preventive Maintenance Checks and Services for Pumping Assembly
Location
Procedure
Not Fully Mission
Item
Interval
Item to
Capable if:
No.
Check/
Service
WARNING
·
Fuel fumes are always present in the vicinity of the
Pumping Assembly. Death or personal injury may result
from the explosion of fuel fumes exposed to an open
flame or spark. Do not permit any smoking, any open
flame or spark producing equipment within 50 feet (15
m) of the Pumping Assembly.
·
Be sure the flex coupling guard is in place.
1
Before
Pump-Engine
Check engine crankcase oil level on dipstick (1). Oil is at correct
Oil level is above upper
Module
level when between upper (2) and lower (3) marks on dipstick. Top mark or below lower
off at oil filler (4) as necessary with:
mark on dipstick.
-25F (-17C) to +40F (4.5C):
MIL-L-46167 OEA (SAE 0W-20)
+5F (-15C) to +120F (49C):
MIL-L-2104 OE/HDO-15/40 (SAE 15W-40)
2-6
|