TM 10-4320-351-14
Section I. DESCRIPTION AND USE OF
OPERATOR'S CONTROLS AND INDICATORS
Figure 2-1. Control Panel
Table 2-1. Control Panel Controls and Indicators
No
Name
Function
1
ENGINE START/RUN/STOP toggle
Momentary START position operates engine starter; RUN position enables
switch
system operating power; STOP position stops engine.
2
Panel Light
Hooded LEDs provide illumination for control panel.
3
INTAKE HEATER ON/OFF switch
Enables power to engine intake air heater.
4
ENGINE HOT indicator
Illuminates RED when engine oil temperature exceeds 275°F (135°C).
5
ALTNTR indicator
Illuminates YELLOW when alternator output is less than battery voltage.
6
EMERGENCY STOP operator
Stops engine when depressed; latches in stop position, must be rotated in
direction of arrows to release.
7
PUMPAGE HOT indicator
Illuminates RED when pumpage temperature exceeds 175°F (79°C).
8
LOW OIL PRESSURE indicator
Illuminates RED when engine oil pressure decreases below safe limits.
9
AUX PUMP/INTAKE HEATER circuit
30 amp, push-to-reset circuit breaker for auxiliary pump and engine intake
breaker
heater.
10
SYSTEM circuit breaker
5 amp, push-to-reset circuit breaker for system electrical power.
11
FAULT LIGHTS ON/BLACKOUT
Enables/disables control panel fault lights and panel lights.
switch
12
PANEL LIGHTS dimmer
Dims or brightens panel lights when rotated.
2-2
|