TM 10-4320-348-14
4.36 GROUND ROD REPAIR AND REPLACEMENT.
This task covers:
a) Removal
b) Installation
INITIAL SETUP
Equipment
Tools
Condition
Tool Kit, General Mechanics
Para
(Appendix B, Section III, Item 1)
2.9 Pump unit removed from system.
4.36 Ground rod removed from earth and ground
cable disconnected from pump.
Figure 4-30. Ground Rod and Attaching Hardware
a.
Removal (Refer to Figure 4-30)
(1)
Loosen screw (1) securing ground cable (2) to ground lug terminal (3).
(2)
Remove ground lug terminal (3) from ground cable (2).
(3)
Loosen hex bolt (4) securing ground cable (2) and rod clamp (5) to grounding rod (6).
(4)
Remove ground cable (2) and rod clamp (5) from grounding rod (6).
b.
Installation.
(1)
Insert ground cable (2) and grounding rod (6) into hole in the rod clamp (5).
(2)
Tighten hex bolt (4) to secure ground cable (2) and rod clamp (5) to grounding rod (6).
(3)
Insert ground cable (2) into hole in ground lug terminal (3).
(4)
Tighten screw (1) to secure ground lug terminal (3) to ground cable (2).
4-64
|