TM 10-4320-347-13&P
4.7. SLAVE CABLE REPAIR AND REPLACEMENT.
This task covers:
a.
Removal
c.
Repair
e.
Installation
b.
Disassembly
d.
Assembly
INITIAL SETUP:
Tools Required
Tool Kit, General Mechanic's (Appendix B, Item 1)
Material's Required
RTV Sealant (Appendix E, Item 5)
Equipment Condition
Pump assembly shut down and cool.
Slave cable disconnected from 24 volt power source.
a.
Removal (Refer to Figure 4-4).
(1) Remove four bolts (1), four washers (2), and junction box cover (3) from motor junction box (4).
(2) Remove two wire nuts (5) from motor wires (6).
(3) Remove strain relief nut (7), disconnect slave cable wires (8) from motor wires (6), and pull slave
cable wires through strain relief.
(4) Remove rubber seal (9) and strain relief nut (7) from slave cable wires (8).
b.
Disassembly. (Refer to Figure 4-5).
(1) Remove six screws (1), six flat washers (2), cap retaining cable (3), and cover (4) from receptacle
(5).
(2) Remove two bolts (6), two lock washers (7), and two wire assemblies (8) from receptacle (5).
(3) Thoroughly remove all RTV sealant from two wire assemblies (8).
c.
Repair.
(1) Remove terminal (9) from wire (10). Discard defective terminal or wire as required.
(2) Strip .50 inch of insulation from new wire (10) and insert wire into terminal (9).
(3) Crimp terminal (9) to captivate wire (10).
4-8
|