TM 10-4320-347-13&P
Table 2-1. Operator Preventive Maintenance Checks and Services
for 35GPM Pump Assembly.
Location
Item
Interval
Item To
Procedure
Not Fully Mission
No
Check/Service
Capable If:
1
Suction Hose Assemblies .
Before
Hose
Check for evidence of tears
Cracks, abrasions, collapsed
or collapsed walls.
walls, or other damage is
detected.
Before
Gaskets
Inspect gaskets for nicks or
Gaskets are brittle or
deterioration.
cracked.
Before
Strainer
Inspect strainer for dirt
Strainer is clogged with
and debris. Remove all
dirt or debris.
dirt or debris from
strainer element.
2
Discharge Hose Assemblies.
Before
Hose
Check for evidence of tears
Cracks, abrasions, collapsed
or collapsed walls.
walls, or other damage is
detected.
Before
Gaskets
Inspect gaskets for nicks or
Gaskets are brittle or
deterioration.
cracked.
3
Nozzle Assemblies .
Before
Body and Spout
Inspect the nozzles for cracks
Cracks, distortion, or
distortion, or other visible
other damage is detected.
damage.
Before
Handle
Press operating handle of
Jerky movements or
nozzle assembly several times
sticking of handle.
to assure that it operates
freely without binding or
sticking.
Before
Gaskets
Check gaskets in couplings
Cracked, torn, or nicked
for damage.
gaskets.
4
Grounding Cable.
Before
Wire and Ends
Inspect for corroded terminals
Broken, frayed, or corroded
or frayed wires.
wire.
2-6
|