TM  10-4320-343-14 Figure   2-4. Connecting   Suction   and   Discharge   Hoses. e . Connect   suction   and   discharge   hoses   as   follows: The   first   pump   in   a   multi-pump   installation   must   use   suction hose  on  suction  side  of  pump  where  vacuum  is  going  to  be encountered. All   other   hoses   in   a   multi-pump   installation   will use   discharge   hoses   making   it   necessary   to   have   positive pressure   (not   to   exceed   30   psi)   on   suction   side   of   pump,   to prevent   hoses   from   collapsing. (1)   Close   suction   valves   (figure   2-4,    1)   and   discharge   valves   (2). (2)   Release   coupling   half   plug   (3)   from   coupling   half   (4). (3)   Connect   suction   hose   (5)   to   coupling   half   (4). (4)   Release   coupling   half   cap   (6)   from   coupling   half   (7). (5)   Connect   discharge   hose   (8)   to   coupling   half   (7). (6)   Connect   suction   hose   (5)   to   upline   source. (7)   Connect   discharge   hose   (8)   to   downline   source. 2-15 NOTE

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business