TM 10-4320-342-24 4-4.  STARTER-GENERATOR REPAIR - continued. (c) Minimum   Speed   for   Regulation.      Operate   starter-generator   at   7,050   rpm,   27   volts   and   200   amperes (stabilization not required), to demonstrate ability to operate at minimum speed for regulation.  Record field current which shall not exceed 10 amperes.  Calculate resistance between terminals B and Aby dividing B to A voltage by field current.  External field circuit resistance (B to A) shall be 0.4 ohms minimum. (d) Compounding.    Operate  starter-generator  at  12,000  rpm  and  30  volts.    Apply  loads  of  0,  50,  100,  150 and 200 amperes.  Record field current.  Field current must rise with increasing load. (e) Commutation.    Reconnect  regulator  and  observe  commutation  at  30  volts,  0  amps,  100  amps  and  200 amps   at   speeds   of   7,050,   10,000   and   12,000   rpm.      Record   the   worst   condition   for   commutation. Commutation must not exceed pinpoints. CAUTION Disconnect  stator  leads  from  terminal  block  and  filter  board  leads  from  bearing retainer  when  conducting  dielectric  test.    Capacitors  embedded  in  radio  noise filters will be damaged if subjected to dielectric test.  A dummy terminal block may be used for this test. (f) Dielectric  Test.    Remove  starter-generator  from  test  stand  and,  while  still  hot  from  testing,  conduct  a  hi- potential to ground test of 220 volts AC rms, 60 Hz for one minutes.  Apply test voltage between each circuit and frame.  No evidence of insulation breakdown shall occur as a result of this test. (g) Starting Test. CAUTION Shunt field shall be open during starting test.  Do not energize unit for more than four seconds during test. (1) Rigidly mount starter-generator by its flange in a horizontal position and lock rotor. (2) Apply and increase voltage between terminals C and E until output torque is 13 foot-pounds.  Record terminal  voltage  and  line  current.    C  to  E  voltage  shall  not  exceed  12  volts.    Line  current  shall  not exceed 400 amperes. (h) Commutator  Run-Out.    Rotate  armature  of  starter-generator  on  its  own  bearings  and  record  commutator total  indicated  run-out  and  the  maximum  bar-to-bar  difference.    Total  indicated  run-out  shall  not  exceed 0.0008 inch.  Bar-to-bar run-out shall not exceed 0.0002 inch. 4-27

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business