TM 10-4320-342-24 4-4.  STARTER-GENERATOR REPAIR - continued. (3) Tests. (a) Maximum  Speed  for  Regulation.    Without  operational  warmup  and  with  regulator  connected  to  the  starter- generator, operate the starter self-excited at 13,000 rpm 28.5 volts DC, and no load.  Calculate resistance between  terminals  B  and  A  by  dividing  B  to  A  voltage  by  the  field  current.    B  to  A  resistance  shall  not  be greater than 35 ohms. Refer to Figure 4-21. (b) Continuous  Operating  Speed  and  Equalizing  Voltage.    With  regulator  connected  to  the  starter-generator, operate   starter-generator   at   12,000   rpm,   30   volts,   200   amperes   for   15   minutes.      Record   the   voltage between  terminals  D  and  E,  inlet  air  temperature  and  winding  or  frame  temperature.    Frame  temperature shall  not  exceed  inlet  air  temperature  by  more  than  175    F   (79.5C).    The  equalizing  voltage  between terminals D and E shall be within the limits shown in Figure 4-18. Figure 4-21.  Equalizing Voltage - Volts 4-26

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business