TM 10-4320-342-24
2-13. WINCH AND CABLES REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Condition
General Mechanics Tool Kit (App B, Sect III,
Battery disconnected (Para 2-7c,
Item 1)
TM 10-4320-342-10)
Material/Parts
General Safety Instructions
Lockwashers (App F, Item 37)
WARNING
Straps (App E, Item 17)
Do not lift more than 50 pounds by yourself and
Splices (App F, Item 42)
bend legs while lifting. Lifting heavy equipment
Insulation Sleevings (App F, Item 43 and 54)
incorrectly can cause serious injury to personnel.
Tags (App E, Item 16)
a.
REMOVAL. Refer to Figure 2-33.
NOTE
There are four nuts on the Winch Control Handle side used to secure the winch to
the 200/600 GPM Pump.
(1)
Remove eight bolts (1), flatwashers (2), and lockwashers (3) and nuts (4). Discard lockwashers.
WARNING
Do not lift more than 50 pounds by yourself and bend legs while lifting. Lifting
heavy equipment incorrectly can cause serious injury to personnel.
(2)
Remove winch (5).
(3)
Cut tie wraps (6) on cables (7 and 8).
(4)
Remove insulation sleevings (9 and 10) from cables (7 and 8).
(5)
Tag electrical wiring.
(6)
Disconnect cables (7 and 8) from 200/600 GPM Pump (11) by cutting splice connector (12) and/or removing nuts
(13) and bolts (14).
b.
INSTALLATION.
WARNING
Do not lift more than 50 pounds by yourself and bend legs while lifting. Lifting
heavy equipment incorrectly can cause serious injury to personnel.
2-93
|