TM 10-4320-342-10
Section IV. OPERATION UNDER UNUSUAL CONDITIONS
12-10. OPERATION IN EXTREME HEAT.
CAUTION
In extreme heat, do not operate 200/600 GPM Pump or damage could occur to
unit.
Do not operate 200/600 GPM Pump if temperature is above 95°F (35°C).
2-11. OPERATION IN SALT WATER AREAS.
Operation in salt water areas accelerates corrosion on bare metal surfaces. Observe the following precautions when
operating 200/600 GPM Pump in this environment.
CAUTION
Do not rinse intake or exhaust areas; damage to equipment may occur.
a.
Position pump in a manner to minimize salt spray from entering air intake.
CAUTION
Do not rinse intake or exhaust areas; damage to equipment may occur.
b.
Following operation in salt water areas, rinse components with clean fresh water to remove salt spray and/or salt
deposits.
2-12. OPERATION IN DUSTY AREAS.
Shutdown 200/600 GPM Pump during dust storms and cover or store unit in shelter.
2-13. EMERGENCY PROCEDURES.
a.
Push Master Switch to shutdown 200/600 GPM Pump.
b.
Close all valves.
2-14. DECONTAMINATION PROCEDURES.
a.
General.
The following emergency procedures can be performed until field NBC DECON facilities are available. Refer to FM 3-3,
FM 3-4, FM 3-5.
2-50
|