TM 10-4320-324-14
2-11. Fording or Swimming.
a.
Before Fording or Swimming.
NOTE
The pumping assembly is transportable through
a body of water up to 30 inches (762 mm) deep.
(1)
Secure tool box cover latch.
(2)
Secure control panel cover.
(3)
Ensure that battery cover retaining bar is
secure.
NOTE
Fuel tank incorporates a vent valve. Valve
must be closed before fording to prevent water
entry. During normal operation, vent valve
must be open. Note instructions on cap (1).
(4)
Remove cap from tank and turn cap over.
(5)
Rotate vent valve selector to CLOSED position
(2).
(6)
Reinstall cap and secure.
b.
After Fording or Swimming.
(1)
Remove fuel tank filler cap and turn cap over.
(2)
Rotate vent valve selector to OPEN position (3).
(3)
Reinstall cap and secure.
2-12. Emergency Procedures.
General. Anytime an emergency arises while operating
the pumping assembly which calls for an immediate
engine shutdown, push the START/STOP switch.
2-22
|