TM 10-4320-324-14
e.
Installation.
(1)
Install new wear ring (6). Widest face toward pump end assembly (10) outlet.
(2)
Install new gasket (5) on pump end assembly (10).
(3)
Install drive end assembly (4).
CAUTION
Make certain that housing to seal plate alinement is correct or damage to unit will result.
(5)
Install 12 lockwashers (3) and tighten 12 nuts (2) to 40 - 42 lb-ft (54 - 57 N.m).
(6)
Install oil drain plug (1).
f.
Follow-on Maintenance.
(1)
Install pump assembly (para 5-23).
(2)
Remove vent cap (12) and pour 8 ounces (240 ml) of lubrication oil into drive end assembly (3).
Replace vent cap. Refer to LO 10-4320-324-12.
END OF TASK