TM 10-4320-324-14
Table 5-2. Starter No-Load Test Specifications
No-Load Test (Includes Solenoid Current)
Volts
Min Amps
Max Amps
Min RPM
Max RPM
11
120
210
9000
13400
(j)
Remove test equipment from starter assembly. If measured performance is above or below performance
specifications remove and test solenoid assembly per paragraph 5-10.
b. Follow-on Maintenance . Install starter (para 4-36).
END OF TASK
5-15
|