TM 10-4320-324-14 5-9.  Starter Assembly Testing (CONT). (3) If pinion rotates freely, perform the following no-load test prior to disassembly. (a) Connect a voltmeter from starter motor terminal to starter motor frame.  Connect negative battery cable to starter motor frame. (b) Mount tachometer to measure armature speed. WARNING Ensure switch is open prior to connecting to starter solenoid.  Electrical shock or physical injury may result if starter is energized while making final battery connection. (c) Connect switch to solenoid battery terminal and solenoid switch terminal. (d) Connect  ammeter  in  series  between  the  positive  side  of  the  battery  and  battery  terminal  on  the  starter solenoid. (e) Connect carbon pile between positive and negative battery terminals. (f) Close switch and adjust carbon pile until voltmeter indicates 11 VDC. (g) Write down ammeter and tachometer readings. (h) Open switch and de-energize starter. (i) Refer to table 5-1 for current and rpm performance specifications. 5-14

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business