TM 10-4320-324-14 4-26.  Spark Arrestor Repair/Replacement (CONT). c. Cleaning/Inspection. WARNING Dry  cleaning  solvent  P-D-680  is  toxic  and  flammable.    Wear  protective  goggles and gloves and use only in a well ventilated area.  Avoid contact with skin, eyes, and  clothes  and  don't  breathe  vapor.    Do  not  use  near  open  flame  or  excessive heat.  The flash point is 100°F-138°F (38°-50°C).  If you become dizzy while using cleaning  solvent,  get  fresh  air  immediately  and  get  medical  aid.    If  contact  with eyes is made, wash your eyes with water and get medical aid immediately. (1) Clean all parts with dry cleaning solvent P-D-680 and wire brush. (2) Inspect all parts for cracks and holes. (3) Replace damaged parts. d. Assembly. (1) Install and aline baffles (9) and plate (8) on base (10). (2) Install cap (7), flat washer (6), and nut (5). e. Installation.  Install spark arrestor assembly (4) with u-bolt (3), clamp base (2), and two nuts (1). f. Follow-on Maintenance. Install exhaust screen (para 4-11). END OF TASK 4-90

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business