TM 10-4320-316-14
(3)
Remove the preservation barrier by tearing around the bottom of the unit.
(4)
Remove the technical publications envelope and accessory sack that are taped to the unit and put them in
a safe place.
WARNING
To avoid serious injury to personnel, always use a suitable lifting device to move or lift
pumping assembly.
(5)
Remove the DED pump from the shipping container by lifting it up and out of the container. Place the unit
into a position where it can be checked for completeness and possible shipping damage.
(6)
Remove the shipping container from the site and retain it if re-use is anticipated. Be sure to remove all
remaining barrier material from the underside of the unit.
c. Checking Unpacked Equipment. To check the unpacked DED pump, perform the following steps.
(1)
Inspect the equipment for damage incurred during shipment. If the equipment has been damaged, report
damage on DD Form 6, Packaging Improvement Report.
(2)
Check the equipment against the packing slip to see if the shipment is complete. Report all discrepancies
in accordance with the instructions as defined within DA PAM 738-750. See that all components of end
item and basic issue items are with the equipment.
(3)
Check to see whether the equipment has been modified.
4-6. INSTALLATION INSTRUCTIONS. Before the DED pump can be properly operated, the unit must be installed into
the system which requires the use of the pump. To install the DED pump into the system, perform the following
instructions.
a. Tools, Test Equipment, and Materials Needed for Installation. The standard tool kit commonly available to
unit level maintenance contains all the tools required to install the DED pump.
b. Assembly of Equipment.
CAUTION
Improper installation of pipe fittings can cause the DED pump to leak badly and could
cause damage to the pump or other system components. Be sure that all threaded male
pipe fittings have four clockwise wraps of teflon tape before fittings are installed.
(1)
Install feet to bottom pan frame (refer to para. 4-25.)
(2)
Install the suction hose to be used in the system onto the suction port of the DED pump. Highest point m
the suction hose should be at the pump.
(3)
Install the discharge hose to be used in the system onto the outlet port of the DED pump.
4-3
|