TM 10-4320-307-10
Chapter 3
OPERATOR MAINTENANCE INSTRUCTIONS
SECTION I. LUBRICATION INSTRUCTIONS
3-1
REFER TO LUBRICATION CHART BELOW.
Lubrication Point
Lubrication Type
Pump Bearing Oil
MIL-L-46167 Grade Arctic or MIL-L-2104 Grade 15W40
Speed Increaser Oil
MIL-L-46167 Grade Arctic or MIL-L-2104 Grade 15W40
Speed Increaser Bearing
Grease
No. 2 Lithium Base Grease
Speed Increaser Pivot
Grease
No. 2 Lithium Base Grease
Engine Oil
MIL-L-46167 Grade Arctic or MIL-L-2104 Grade 15W40
SECTION II. TROUBLESHOOTING PROCEDURES
3-2
GENERAL. Troubleshooting at the operator level requires you to locate any trouble as quickly as
possible. Once trouble is located, repair or replace the part if you are authorized to do so or determine if a
higher category of maintenance is required. Repairs at the operator level are limited by tools, test equipment,
and replacement parts allocated to that level.
WARNING
Troubleshooting procedures may require that checks be made while the
engine is running. Use extreme care to prevent contact with high
temperature exhaust electrical or moving parts. Proper care must be taken
to provide efficient ventilation when running the engine indoors; exhaust
gases contain carbon monoxide which is odorless and a deadly poison.
Spilling diesel fuel on or about a hot engine may cause an explosion and
serious injury.
3-3
TROUBLESHOOTING.
a.
Table 3-1 lists common problems that may occur during operation or maintenance of the pumping
assembly. Follow these steps to use Table 3-1.
(1)
Find the problem under MALFUNCTION.
(2)
Check for possible causes of the problem under TEST OR INSPECTION.
(3)
Use the procedures under CORRECTIVE ACTION to correct the problem.
b.
This manual cannot list all troubles that may occur, nor everything to check, nor all possible procedures
to correct troubles listed. If trouble is not listed in Table 3-1 or is not corrected by procedures under
CORRECTIVE ACTION, notify unit maintenance.
3-1
|