TM 10-4320-307-10
Table 2-2. Operator/Crew Preventive Maintenance Checks and Services - (Cont)
Item
Location
Not Fully
No.
Interval
Item to
Procedure
Mission Capable
Check/Service
if:
57
Weekly
Conduit
Visually inspect the conduit runs for security of all connectors
Loose or missing
Layout
and wiring.
conduit clamps.
Check for loose or missing conduit clamps and damaged or
broken cable ties.
Check conduit for frayed or broken insulation.
58
Weekly
Junction
Check junction boxes for secure attachment to mountings.
Cracked or loose
Box
Visually inspect for cracks in welds around the junction box
mounting, loose
assembly.
connectors.
Check connectors mounted to junction box for security of at-
tachment.
59
Weekly
Network
Check network cables for frayed insulation, broken wires, and
Bare or broken
Cable
other damage.
wires are found.
Check for loose connections.
60
Weekly
Radiator As-
Check radiator assembly for loose or missing mounting hard-
Low coolant lev-
sembly (1)
ware (2) and coolant level.
el. Loose or dam-
aged compo-
nents. Category
Class II coolant
leaks.
2-51
|