LO 10-4320-343-12
Table 1. Lubricant Table for 350 GPM Pump Assembly Engine Crankcase
lubricant for all expected
q lf OEA lubricant is required to meet low expected temperature range, OEA lubricant is to be used in lieu of OE/HDO-10
temperatures where OE-HDO-10 is specified.
NOTES:
1. EXTENDED COLD TEMPERATURES. Proceed as follows for operation of equipment in extended cold
temperature areas below -10F (-23C). Remove lubricant prescribed in table 1 for temperatures above
-10F (-23C). Clean parts with dry cleaning solvent (SD, type II) or equivalent. Lubricate with lubricant specified
in Table 1 for the specific component to operate at temperatures of -10 and below (eg. OEA for engine, GAA for
wheel bearings).
2. OIL FILTER. Replace oil fitter with every crankcase oil change. Remove element, clean seat, and install new
element. After servicing crankcase, operate engine for 5 minutes and check oil filter for leakage. Check oil level
and bring to top mark on dipstick.
3. ENGINE CRANKCASE. Drain after operation when hot. To drain, remove plug at bottom of crankcase sump
Clean and inspect plug. Remove filler cap, fill sump with 8.5 qts (8.04L) of oil OE/HDO to bring level to top mark
on dipstick. ON new or overhauled engines, drain oil after 50 hours of operation and service crankcase.
4. PUMP/BEARING CAVITY. Check oil level at sight gauge. TO add oil, remove vent fitting. Use OE/HDO and fill
until oil is in view in sight gauge. Install vent fitting.
5. WHEEL BEARING. Pack wheel bearings as follows:
a.
Position assembly on jack stands.
b.
Remove grease cap.