TM 5-4320-308-13 4-9.  REPAIR Y-CONNECTORS This task covers: a. Cleaning/Inspection b. Repair INITIAL SETUP Materials/Parts Equipment Condition Diesel fuel oil (Item 2, Appendix E) Para Condition Description 2-1 Y-Connectors removed from pumping assembly. General Safety Instructions Well-ventilated area required. CLEANING/INSPECTION: WARNING Death or serious injury could occur if fuel is not handled carefully.  Use in a well-ventilated area away  from  open  flame,  arcing  equipment,  ignition  sources,  heaters,  or  excessive  heat.    Always store fuel in proper, marked containers. DO NOT SMOKE. Death or serious injury could occur if compressed air is directed against the skin.  Do not use compressed air for cleaning or drying unless the pressure is/has been reduced to 30 psi (2.06 bar) or less.  When working with compressed air always use chip guards, eye protection, and other personal protective equipment. 1     Clean   male-double   female   Y-connector (1)   and   female-double   male   Y-connector   (2) with clean diesel fuel and dry with compressed air. 2     Inspect   for   cracks,   score   marks,   burrs, signs of deterioration, and obvious damage. REPAIR: If parts are not repairable, replace. 4-16

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business