b. The pump discharge assembly is mounted on
pot (B, fig. 4-2 ). It closes to prevent discharged
the side of the diaphragm opposite the suction
water from returning to the diaphragm pot on the
assembly. It controls the fluid movement at the
upward stroke of the diaphragm (A, fig. 4-2).
outlet side of the pump. It consists mainly of a
c. An accumulator is mounted on the suction
check valve mounted in a housing. This check valve
check valve housing. This accumulator reduces the
allows water to flow out of the pump as the
surging of the fluid as the pump diaphragm
diaphragm is forced downward into the diaphragm
changes stroke direction. At the end of the intake
|