TM 9-2330-398-24
1.
Using wire cutters, cut electrical wire (2) to required length.
2.
Using electrical repair kit, install quick-disconnect terminal (1) on electrical wire (2).
3.
Slide band marker (3) and electrical connector shell (6) on electrical wire (2).
4.
Using electrical repair kit, install electrical contact (4) on electrical wire (2).
5.
Install slotted washer (5) on electrical contact (4), and slide electrical connector shell (6) over electrical contact (4).
Figure D-7. Electrical Lead 12275540
NOTE
Gasket material comes in 9 sq ft (0.8 sq m) sheets. Check to see if unused gasket material
is available to avoid ordering excess amounts.
Table D-9. Gasket 12380153
Part Number
Length
HH-P-96
3.88 in. (8.85 cm)
NSN 5330-00-634-8264