TM 9-2330-398-24
3-32. DRAIN VALVE ASSEMBLY AND TUBING REPLACEMENT.
b. INSTALLATION
1.
Install drain valve assembly (4) on semitrailer with eight screws (5) and washers (6).
2.
Install diaphragm assembly (2) and nipple (3) on drain valve assembly (4).
3.
Install tube (9) and straight adapter (10) to drain valve assembly (4).
4.
Install tube (9) and elbow (11) on diaphragm valve (4).
5.
Install tube (1), insert (8), and elbow (7) on drain valve assembly (4).
6.
Install tube (1) on diaphragm valve assembly (2).
FOLLOW-ON MAINTENANCE:
Install float valve (para 3-40).
Disconnect ground (refer to TM 9-2330-398-10).
3-101
|