3-28.
ENGINE HIGH-TEMP THERMOSTAT CONTROL SWITCH REPLACEMENT.
3.
Remove nut (7), lockwasher (8), terminal (9), washer (10), two insulated washers (11), insulated sleeve (12), two
insulated washers (13), and switch (6) from switch bracket (3). Discard lockwasher.
b.
INSTALLATION
1.
Install switch (6) on switch bracket (3) with nut (7), new lockwasher (8), terminal (9), washer (10), two insulated
washers (11), insulated sleeve (12), and two insulated washers (13).
2.
Install switch bracket (3) on exhaust manifold (1) with screw (2).
3.
Connect two leads (4 and 5) to switch (6).
FOLLOW-ON MAINTENANCE:
Install air shutter assembly (para 3-26).
Disconnect ground (refer to TM 9-2330-398-10).
3-93
|