TM 9-2330-398-24
Table 2-1. Unit Preventive Maintenance Checks and Services (PMCS) FOR THE M969A2 (continued)
Item
Item to
Not Fully Mission
No.
Interval
Check/ Service
Procedure
Capable If:
6
Semiannual
Bogie
a.
Position semitrailer on hard level surface
Assembly
with front resting on landing gear. Jack and
block frame. Remove tire and wheel
assemblies (para 2-62).
NOTE
Clean axle and suspension system
with water and fiber brush to allow
for careful inspection.
b.
Inspect general condition of trunnion tube,
axles, and leaf springs. Look for cracks or
damage. If cracked or damaged, notify
Direct Support maintenance
CLIP
LEAF SPRING
c.
Check tightness of U-bolts and clips on leaf
springs. Tighten loose U-bolts and clips. If
damage or wear is evident, notify Direct
Support maintenance.
d.
Check tightness of U-bolts and screws on
leaf spring cap and seat. Tighten loose U-bolts
and screws. If damage or wear is evident,
notify Direct Support maintenance.
2-8
U-BOLT
LEAF SPRING
CAP (HIDDEN)
TRUNNION
TUBE
AXLE
(HIDDEN)
|