TM 9-2350-398-24
2-134. EMERGENCY VALVE A CONTROL HANDLE REPAIR (continued).
d.
ASSEMBLY
1.
Install control handle (3) and trip bracket (7) in emergency valve A control handle mounting bracket (9) with shaft
(8) and straight pin (10).
2.
Install plate (6) and U-bolt (5) on trip bracket (7) with two nuts (4).
e.
INSTALLATION
Install emergency valve A control handle mounting bracket (9) on toolbox (2) with two screws (1) and nuts (11).
FOLLOW-ON MAINTENANCE:
Connect emergency valve A control cables (2-133).
Adjust control cables (2-133).
Disconnect ground (refer to TM 9-2330-398-10).
2-295
|