TM 9-2330-398-24 2-113.  VAPOR RECOVERY SYSTEM REPLACEMENT  (continued). e. REMOVAL OF GROUND RECEPTACLE 1 Remove screw (46) self-locking nut (43), and ground lead (48) of ground receptacle (42) from bracket (44).  Discard self-locking nut. 2. Remove  two  screws  (47)  and  self-locking  nuts  (45)  and  receptacle  (42)  from  bracket  (44).    Discard  self-locking nuts. 3. Remove screw (46), self-locking nut (43), and bracket (44) from semitrailer.  Discard self-loc king nut. f. INSTALLATION OF GROUND RECEPTACLE 1. Install bracket (44) on semitrailer with screw (46) and new self-locking nut (43). 2. Install receptacle (42) on bracket (44) with two screws (47) and new self-locking nuts (45). 3. Install ground lead of ground receptacle (42) on bracket (44) with screw (46) and new self-locking nut (43). FOLLOW-ON MAINTENANCE: Disconnect ground (refer to TM 9-2330-398-10). 2-250