TM 9-2330-398-24 2-105.  ENGINE ELECTRICAL CONDUIT REPLACEMENT. This Task Covers: a.  Removal  b.  Installation Initial Setup: Tools/ Test Equipment: Equipment Conditions: • General mechanic's tool kit (Item 4, Appendix B) • Semitrailer uncoupled (refer to TM 9-2330-398-10). • Semitrailer bonded and grounded (refer to Materials/Parts: TM 9-2330-398-10). • Self-locking nut (2) (Item 169, Appendix F)  a • Negative battery cable disconnected (para 2-33). • Electrical lead assembly (12267081) removed (para 2-102). a.  REMOVAL WARNING: When troubleshooting an electrical malfunction or performing electrical maintenance,  ALWAYS  disconnect  Intervehicular  electrical  cable  from  semitrailer and disconnect negative battery cables at batteries.  Failure to follow this warning may create a spark and explosion, resulting In serious Injury or death to personnel. 1.    Loosen  two  conduit  connectors  (2)  from  engine control panel (1) and conduit mounting plate (6). 2.    Remove two capscrews (4) and self-locking nuts (5) from mounting plate (6). 3.    Remove mounting plate (6) and engine electrical conduit (3) from engine control panel (1) 4.    Remove two conduit connectors (2) from conduit (3). b.  INSTALLATION 1.    Install two conduit connectors (2) on conduit (3). 2.    Install   conduit   (3)   on   control   panel   (1)   and mounting plate (6). 3.    Install  two  capscrews  (4)  and  new  self-locking nuts (5) on mounting plate (6). 4.    Tighten two conduit connectors (2). FOLLOW-ON MAINTENANCE: • Disconnect ground (refer to TM 9-2330-398-10). • Connect negative battery cable (para 2-33). • Install electrical lead assembly (12267081) (para 2-102) 2-221

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business