TM 9-2330-272-14
2-20. GRAVITY DISCHARGE OF FUEL (Cont).
k. When operation is complete, close gravity discharge valve (3) and manifold (2) valve. Close emergency
relief valve by pushing in on operating control lever,
l. Close and latch manhole fill cover (para 2-14).
m. Drain and remove transfer hose from fuel receptacle and gravity discharge valve (3) outlet. Install cap on
outlet.
WARNING
Walk grounding cable back to reel when stowing ground cable. DO NOT let go of
grounding cable until fully wound onto reel. Failure to follow this warning may result in
serious injury to personnel.
n. Disconnect bonding and grounding connections (para 2-13).
o. Stow fire extinguishers
GRAVITY DISCHARGE OF FUEL (M131A4)
NOTE
All fuel valves are in closed position unless otherwise indicated.
2-48
|