TM   9-2330-272-14 2-18.   BOTTOM   LOADING   (PREFERRED   METHOD)   (Con’t). h. Remove cap from pump intake valve (5) outlet. Connect transfer hose (7) from pump intake valve outlet to fuel source. i. Open emergency relief valve of compartment (1, 9, 10, or 12) to be loaded by pulling operating control Iever outward. j. Open manifold (2) valve of compartment (1, 9, 10, or 12) to be loaded. k. Open gravity discharge valve (3), pump intake valve (5), and pump discharge valve (6). WARNING DO NOT breathe fuel fumes. They are toxic and can cause serious medical problems. Failure to follow this warning may result in serious injury or death to personnel. Give IMMEDIATE medical attention to personnel exposed to hydrocarbon or toxic vapors.   Signs   of   distress   are   weakness,   nausea,   coughing   or   intoxication, nosebleed  or  cramps,  or  other  unusual  symptoms.  Qualified  personnel  able  to administer artificial respiration and simple first aid must be present. l. Start auxiliary engine (para 2-15). Fuel wiII begin to flow. Have assistant watch marker on fuel level gage inside manhole opening to determine fuel level in tank. DO NOT overfill. m. When operation is complete, shut off auxiliary engine (para 2-15). Close pump discharge valve (6), pump intake valve (5), gravity discharge valve (3), and manifold (2) valve. Close emergency relief valve by pushing in on operating control lever. n. Close and latch manhole fill cover (para 2-14). o. Drain and remove transfer hose (7) from gravity discharge valve (3) outlet and pump discharge valve (6) outlet Install caps on outlets. p. Drain and remove transfer hose (7) from pump intake valve (5) outlet and fuel source. Install capon outlet. WARNING Walk grounding cable back to reel when stowing grounding cable. DO NOT let go of grounding cable until fully wound onto reel. Failure to follow this warning may result in serious injury to personnel. q. Dsconnect bonding and grounding connections (para 2-13). r.  Stow  fire  extinguishers. 2-31

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business