TM 9-2330-272-14
4 - 9 7 . E M E R G E N C Y R E L I E F V A L V E O P E R A T O R C O N T R O L C A B L E A S S E M B L Y
REPLACEMENT (Cont).
2.
3 .
4.
5 .
6.
7.
8 .
9 .
10.
CAUTION
Use caution when installing control cable assembly at straps. When securing control
cable assembly under straps, a soft-faced hammer should be used to tap straps into
place. Improper handling of straps will cause them to break.
Gently bend straps over control cable assembly to secure to frame.
Connect tubing (2) to connector (19) at operator control (17) inside cabinet and tighten nut (18).
Connect wire rope (3) to operator control (17) (para 4-96).
Connect tubing (2) to connector (4) at emergency reilef valve (1) and tighten nut (5).
Connect wire rope (3) to emergency relief valve (1) and tighten cable clamp (7) U-bolt (6), and two nuts (8).
Connect tubing (9) to connector (19) at operator control (17) and tighten nut (18).
Connect wire rope (14) to operator control (17) (para 4-96).
Connect tubing (9) to connector (15) at emergency relief valve shutoff (11) and tighten nut (16).
Connect wire rope (14) to emergency relief valve shutoff (11) and tighten cable clamp (12), U-bolt (13), and two
nuts (10).
FOLLOW-ON TASKS:
Lubricate emergency relief valve operator control cable assembly (Chapter 3, Section I).
Check operation of emergency relief valve operator control cable assembly and adjust as required (para 4-96).
4-213
|