TM 9-2330-272-14
4-77. AUXILIARY ENGINE SEDIMENT STRAINER MAINTENANCE (Cont).
b.
DISASSEMBLY
1.
Loosen thumbscrew (7) and remove bowl (10) and
gasket (8) from strainer head (6). Discard gasket.
2.
Remove strainer element (9) from bowl (10).
c.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, Is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
The solvents flash point is 100°F-138°F (38°C-59°C). If you become dizzy while
using cleaning solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes and get medical aid.
1.
Clean strainer head, strainer element, and bowl with dry cleaning solvent. Dry thoroughly.
2.
Inspect strainer head and bowl for cracks, breaks, and other damage. Replace bowl if cracked, bent, or
otherwise damaged. If strainer head is damaged, replace entire sediment strainer.
3.
Inspect strainer element for corrosion and deterioration, Replace strainer element if corroded or deteriorated.
d .
ASSEMBLY
1.
Position strainer element (9) in bowl (10)
NOTE
Tighten thumbscrew only enough to prevent fuel leakage.
2.
Position new gasket (8) and bowl (10) in strainer head (6) and tighten thumbscrew (7).
4-161
|