TM 9-2330-272-14
4-67. NOZZLE ASSEMBLY MAINTENANCE (M131A4C AND M131A5C) (Cont).
b.
DISASSEMBLY
Remove cap (4), adapter (5), strainer (6), and
gasket (7) from nozzle (8). Discard gasket.
c. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles
and gloves, and use only In a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
The solvents flash point is 100°F-138°F (38°C-59°C). If you become dizzy while
using cleaning solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes and get medical aid.
1.
Clean all parts with dry cleaning solvent. Dry thoroughly.
2.
Inspect all parts for damage. Replace damaged parts.
d . A S S E M B L Y
Install new gasket (7), strainer (6), adapter (5), and cap (4) on nozzle (8).
4-142
|