TM 9-2330-272-14
4-37. AIR FILTER REPLACEMENT (Cont).
b. AIR TUBE INSTALLATION
1.
2.
3.
Cut 12 in. (30.5 cm) and connector from end of air tube (1).
4
Cut connector front air tube (5) as close to connector as possible.
Install nut (10), insert (11) and sleeve (12) on air tube (1). Sleeve and nut should be 1/4 in. (6.4 mm) from end of air
tube.
Apply antiseizing tape to straight adapter (13) and install on nut (10).
5.
Repeat steps 3 and 4 for air tube (5).
6.
Cut required length of new air tube (17).
7.
Install two nuts (16), inserts 915), and sleeves (14) on air tube (17). Slide nuts over sleeves.
TA702727