TM 9-2330-272-14
4-27. WIRING REPAIR (Cont).
e.
PLUG ASSEMBLY REPAIR
NOTE
Male and female inserts are replaced the same way. This procedure covers male insert
replacement.
1.
Remove coupling nut (16) from grommet retaining nut (14).
2.
Remove grommet (17) from coupling nut (16). Cut insert (18) from wire (15). Discard insert.
3.
Remove grommet (17), coupling nut (16), and grommet retaining nut (14) from cable (13).
4.
Strip insulation off wire (15) equal to depth of new insert (18).
5.
Thread cable (13) through grommet retaining nut (14), coupling nut (16), and grommet (17).
6.
Position new insert (18) on wire (15) and solder.
7.
Press grommet (17) into coupling nut (16) until seated.
8.
Install coupling nut (16) on grommet retaining nut (14).
f .
RECEPTACLE REPAIR
NOTE
Male and female inserts are replaced the same way. This procedure covers male insert
replacement.
1.
Remove receptacle (22) from grommet retaining nut (20).
2.
Remove grommet (23) from receptacle (22). Cut insert (24) from wire (21). Discard insert.
3.
Remove grommet (23), receptacle (22), and grommet retaining nut (20) from cable (19).
4-40
|