TM 9-2330-272-14
Table 4-2. Organizational Troubleshooting (Cont).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
15. SEMITRAILER PULLS TO ONE SIDE.
Step 1.
Check service brake adjustment.
Adjust service brakes (para 4-31).
Step 2.
Check wheel bearing adjustment.
Adjust wheel bearings (para 4-44).
Step 3.
Check for loose suspension springs.
Tighten U-bolts (para 4-52).
LANDING GEAR
16. DIFFICULT OPERATION.
Check for bent operating shaft.
Replace operating shaft (para 4-50).
AUXILIARY ENGINE
WARNING
Do not slave start auxiliary engine, Slave starting may cause battery to spark and cause
an exploslon. Failure to follow this warning may result in injury or death to personnel.
17. ENGINE WILL NOT START.
Step 1.
Step 2.
Step 3.
Step 4.
Check for defective panel power switch.
Replace panel power switch (para 4-80).
Check for defective ignition switch.
Replace ignition switch (para 4-80).
Check for defective starter switch.
Replace starter switch (para 4-80).
Check for defective panel power circuit breaker.
Replace panel power circuit breaker (para 4-81).
4-16
|