TM 9-2330-272-14
Table 4-1. Organizational Preventive Maintenance Checks and Services (PMCS) (Cont).
SSEMIANNUAL
AANNUAL
BBIENNIAL
ITEM
INTERVAL
ITEM TO BE
NO.
INSPECTED
S
A
B
PROCEDURES
9
FILTER-
SEPARATOR
(M131A4C AND
M131A5C)
Change filter elements and go-no-go fuses. Record date on filter-se-
parator housing (para 4-86, 4-87, or 4-88).
10
PIPING
Service sediment strainer (para 4-93).
11
FIRE
EXTINGUISHERS
WARNING
Handle charged fire extinguisher cylinders with care.
DO NOT jar or expose to temperature above 140°F
(60°C).
NOTE
Refer to TB 5-4200-200-10 for guidance on fire extin-
guisher servicing.
a. Remove fire extinguisher from mounting bracket and weigh. Fill
out maintenance request (DA Form 2407) or exchange request
(DA Form 2402) for cylinders requiring recharging.
b. Check mounting bracket for secure attachment to semitrailer.
Check that lockup handle moves freely and is not damaged.
c. If equipped, check that plastic indicator on top of fire extinguisher
is intact.
NOTE
Some fire extinguishers have a safety wire-lead or
plastic seal attached to pull pin.
d. Check that safety wire-lead or plastic seal is not broken or miss-
ing.
e. Check that tube is not kinked and nozzle is free of obstructions.
f. Check that the fire extinguisher tag is securely attached. Check
for date of last inspection/recharge.
4-7
|