TM 9-2330-272-14
Section Il. SERVICE UPON RECEIPT
Page
Paragraph Title
Number
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2
Inspection Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2
Servicing Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2
4-4.
GENERAL.
When anew, used, or reconditioned semitrailer is first received, determine whether it has been properly
prepared for service and is in condition to perform its mission. Follow the inspection instructions in paragraph 4-5 and
servicing instructions in paragraph 4-6.
4-5.
INSPECTION INSTRUCTIONS.
a. Refer to DD Form 1397 for procedures on unpacking the semitrailer.
b. Remove all straps, plywood, tape, seals, and wrappings.
WARNING
Dry cleanlng solvent, P-D-680, is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
The solvents flash point is 100°F - 138°F (38°C - 59°C). If you become dizzy while
using cleaning solvent, immediately get fresh air and medical help. If solvent contacts
eyes, immediately wash your eyes and get medical aid.
c. Remove rust preventive compound from coated exterior parts of the semitrailer using dry cleaning
solvent (Item 16, Appendix E) and rags (Item 14, Appendix E).
d. Inspect the semitrailer for damage incurred during shipment. Check also to see if the equipment has
been modified.
e. Check the equipment against the packing list to ensure that the shipment is complete. Report any
discrepancies in accordance with instructions in DA Pam 738-750.
4-6.
SERVICING INSTRUCTIONS .
a. Perform all operator/crew and organizational PMCS. Schedule the next PMCS on DD Form 314.
b. Lubricate all lubrication points as described in Chapter 3, Section I, regardless of interval.
c. Report any problems on DA Form 2404.
d. Perform a break-in road test of 25 mi (40 km) at a maximum speed of 50 mi/h (80 km/h).
4-2
|