TM 9-2330-272-14
LUBRICATION CHART
SEMITRAILER, TANK: FUEL, 5000 GALLON, 4-WHEEL
M131A4 (NSN 2330-00-994-9459)
M131A5 (NSN 2330-00-226-6079)
SEMITRAILER, TANK: FUEL SERVICING,
5000 GALLON, 4-WHEEL
M131A4C (NSN 2330-00-994-9458)
M131A5C (NSN 2330-00-226-6080)
Intervals (on-condition or hard time) and related
man-hour times are based on normal operation. The
man-hour time specified is the time you need to do all
services prescribed for a particular interval. De-
crease the intervals if your lubricants are contami-
nated, or if you are operating equipment under
adverse conditions, including longer-than-usual op-
erating hours. The intervals may be extended during
periods of low activity. If extended, adequate preser-
vation precautions must be taken.
Dotted Ieader lines indicate Iubrication is required on
both sides of the equipment.
WARNING
Dry cleaning solvent, P-D-680, is toxic and
flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated
area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT
use near open flame or excessive heat. The
solvents flash point is 100°F - 138°F
(38°C - 59°C). If you become dizzy while using
cleaning solvent, immediately get fresh air and
medical help.
If solvent contacts eyes,
immediately wash your eyes and get medical
aid.
Clean all fittings and area around lubrication points
with dry cleaning solvent (ltem 16, Appendix E) or
equivalent before lubricating equipment. After lubri-
cation, wipe off excess oil or grease to prevent accu-
mulation of foreign matter.
The lowest level of maintenance authorized to lubri-
cate a point is indicated in parentheses by use of the
following: (C) Operator/Crew; or (O) Organizational
Maintenance.
3-2
|