TM 55-4920-383-13&P
Table 3-2. Performance Checks-Continued
Step
3
Action
Set CAPACITANCE
RANGE switch (6)
to LOW ADJ posi-
tion and DISPLAY
SELECT switch (8)
to CAP (pF) posi-
tion.
Set CAPACITANCE
RANGE switch
(6) to HIGH ADJ
position and DIS-
PLAY select
switch (8) to
CAP (pF).
Normal
indication
Digital display (7)
reads LOW
value stamped
on CAP STAND-
ARDS placard
(5).
Digital display (7)
reads HIGH
value stamped
on CAP STAND-
ARDS placard
(5).
Abnormal
indication
Digital display
does not read
LOW value
stamped on
CAP STAND-
ARDS placard
(5).
Digital display (7)
does not read
HIGH value
stamped on
CAP STAND-
ARDS placard
(5).
Corrective
action
Remove protective
cap and use
screwdriver to ad-
just LOW ADJ con-
trol (2) until digital
display (7) reads
LOW value stamped
on CAP STANDARDS
placard (5). If normal
indication cannot be
obtained, refer Test
Set to higher level of
maintenance.
Remove protective
cap and use screw-
driver to adjust HIGH
ADJ control (3) until
digital display (7)
reads HIGH value
stamped on CAP
3-9
|