TM  55-4920-383-13&P Table   2-1.   Front   Panel   Controls,   Indicators   and   Connectors-Continued Fig.   2-1 item  no. 6 Panel  component CAPACITANCE-RANGE   (pF) switch 200,  1000,  4000, 8000  positions HIGH  ADJ-position LOW   ADJ-position Digital   Display DISPLAY  SELECT  switch Function Selects  range  and  resolution  of  capacitance measurement   as   follows: CAPACITANCE  RANGE 200 pF 1000  pF 4000 pF 8000 pF RESOLUTION 0.05  pF 0.25  pF 1.0  pF 2.0  pF High  range  check  of  capacitance  meas- urement   circuitry. Low  range  check  of  capacitance  meas- urement   circuitry. Displays   measured   capacitance   in   picofarads or   resistance   in   megohms.   Display   is direct   reading   in-line   numeric   type. Selects   capacitance   measurement   mode   or resistance  measurement  mode  of  Test  Set. 2-5