TM 55-4920-383-13&P Table  1-1.  Leading  Particulars-Continued Characteristic Insulation resistance measurement Range Accuracy,  scales,  and resolution Measurement capabilities Description 0.1-100,000  Megohms  in  six  ranges. Scale Accuracy 0.1-1  Meg 1-10 Meg 10-100 Meg 100-1000 Meg 1000-10,000 Meg 10,000- 100,000 Meg 5% reading 5% of reading 5% of reading 5% of reading 10% of reading 15% of reading Resolution .01 Meg 0.1 Meg 1 Meg 10 Meg 100 Meg 1000 Meg Selector switch provides means for testing resistance between the following: a) Unshielded conductor and compensator conductor to ground. b) Coaxial conductor to ground. c) Coaxial conductor to unshielded conduc- tor. d) Coaxial conductor to compensator conductor. 1-5