TM 55-4920-383-13&P
NOTE
If potentiometer A5R2 requires adjustment, perform measuring circuit alignment
after power supply A5 alignment is complete.
(4) Connect digital voltmeter (+) to points listed in table 4-5 and check that digital
voltmeter reads within minimum and maximum values for each test point. If voltage is
not within minimum and maximum values, replace power supply board A5.
Table 4-5. Power Supply Voltages
Test
point
+15 V
-15 V
+14 V
+10 V
+9 V
-6 V
+5V LOG
+5V DIS
- 1 V
+2 2V
-50 V
Digital voltmeter reading
Minimum (vdc)
*+15.00
-14.25
+13.30
+9.50
+8.55
-5.70
+4. 75
+4.75
-0.95
+18.00
-45.00
*Adjust potentiometer A5R2 for exact value.
Maximum (vdc)
*+15.00
-15.75
+14.70
+10.50
+9.45
-6.30
+5.25
+5.25
-1.05
+26.00
-55.00
b.
Measuring Circuitry. Measuring circuitry alignment must be performed after re-
placing digital board Al, analog board A2, simulator board A3, air capacitor board A4, power
4-32
|