TM 55-2915-335-30&P
2-18. ARMATURE AND FIELD TUBE ASSEMBLY - lNSPECT/REPLACE (Cont)
2-18
f. Remove washers (9 and 10) from ends of armature (2) shaft.
g. Slide impeller (11) from housing. Be careful not to damage impeller seal surface.
3. CLEANING
a. Clean Armature
Compressed air aimed at the skin can cause serious injury or death.
Wear goggles and never use over 30 psi (207 kPa) of compressed air
for cleaning.
Cleaning solvent can be hazardous to your health. Use solvent only
in well ventilated areas. Avoid breathing solvent vapors. Do not use
solvent near an open flame or other source of high heat. Always wear
gloves, apron, and goggles when using cleaning solvent. Store solvent
in approved metal container only.
GO TO NEXT PAGE
2-57
|