Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: ARMATURE AND FIELD TUBE ASSEMBLY - lNSPECT/REPLACE (Cont)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM    55-2915-335-30&P 2-18.  ARMATURE  AND  FIELD  TUBE  ASSEMBLY  -  lNSPECT/REPLACE  (Cont) 2-18 f. Remove washers (9 and 10) from ends of armature (2) shaft. g. Slide impeller (11) from housing. Be careful not to damage impeller seal surface. 3.  CLEANING a. Clean Armature Compressed air aimed at the skin can cause serious injury or death. Wear goggles and never use over 30 psi (207 kPa) of compressed air for  cleaning. Cleaning solvent can be hazardous to your health. Use solvent only in well ventilated areas. Avoid breathing solvent vapors. Do not use solvent near an open flame or other source of high heat. Always wear gloves,  apron,  and  goggles  when  using  cleaning  solvent.  Store  solvent in approved metal container only. GO TO NEXT PAGE 2-57