TM 5-5430-219-13
Table 3-2.
Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
Step 1.
Check for missing or loose washers (1) and hex-head
capscrews (2).
Replace missing screws and washers, Torque screws to
30 in-lb (3.41 Nm).
Step 2.
Check preformed packing (3) between closure plate (4) and
tank fitting (5) for nicks, breaks, and compression.
Replace preformed packing (para 3-17).
10.
FILLER/DISCHARGB ASSEMBLY LEAKS BETWEEN CLOSURE PLATE AND FLANGED
ADAPTER.
Step 1.
Check for missing or loose nuts (6), lockwashers (7), thread
seal washers (8), and hex-head capscrews (9).
Replace missing screws (9), washers (7 and 8), and nuts
(6). Torque screws to 30 ft-lb (40.95 Nm).
Step 2.
Check flange gasket (10) for damage or breaks.
Remove flanged adapter (11) from closure plate (4) and
replace damaged flange gasket (para 317).
11.
FILLER/DISCHARGB ASSEMBLY LEAKS BETWEEN FLANGED ADAPTER AND QUICK-
DISCONNECT COUPLING.
Remove quick-disconnect coupling (12) from flanged adapter (11) and
check elbow gasket (13) for damage or breaks.
Replace gasket as required (para 3-17).
12.
FILLER/DISCHARGB ASSEMBLY LEAKS THROUGH HARDWARE OR WILL NOT ASSEMBLE.
Check all filler/discharge hardware for cracks, damage, and wear.
Replace required hardware.
3-14
CORRECTIVE ACTION
9. FILLER/DISCHARGE ASSEMBLY LEAKS BETWEEN CLOSURE PLATE AND TANK FITTING