TM 5-5430-219-13
Cleaning solvent, P-D-680, used to clean parts, is potentially
dangerous to personnel and property. It produces toxic and
flammable fumes.
Use only in well-ventilated areas. Avoid
repeated and prolonged skin contact.
Do not use near an open
flame or excessive heat.
The flash point of solvent is 100°F to
138°F (38°C to 59°C).
SERVICE
1 Clean tank exterior with detergent and hot water.
2 Clean mechanical parts with cleaning solvent and dry thoroughly.
3 Inspect all mechanical parts for cracks, dents, breaks, or wear.
Replace or repair if unserviceable.
4 Inspect gaskets and preformed packing for deterioration, distortion,
cracks, or breaks.
Replace when serviceability is doubtful.
ASSEMBLY AND INSTALLATION
NOTE
The drain end of the tank will unroll first.
1 Unroll tank and unfold sides, using tank handles to position tank.
2 Install drain fitting assembly (para 3-18).
3 Install vent and pipe assembly (para 3-15).
4 Install filler/discharge assemblies (para 3-17).
Section VII.
PREPARATION FOR STORAGE OR SHIPMENT
3-20. GENERAL.
Prior to storage, the tank should be disassembled, purged of all
residual fuel and fumes, cleaned, and preserved along with its components
for future use.
3-41
|