TM 5-5430-219-13
SERVICE
Cleaning solvent, P-D-680, used to clean parts is potentially
dangerous to personnel and property. It produces toxic and
flammable fumes.
Use only in well-ventilated areas. Avoid
repeated and prolonged skin contact.
Do not use near an open
flame or excessive heat.
The flash point of solvent is 100°F to
138°F (38°C to 59°C).
1 Clean all parts with cleaning solvent and dry thoroughly.
2 Clean all gasket sealing surfaces thoroughly with detergent and hot
water.
3 Inspect all mechanical parts for cracks, dents, breaks, or wear.
Replace or repair if unserviceable.
4 Carefully inspect gaskets for deterioration, distortion, cracks, or
breaks.
Replace when service is doubtful.
ASSEMBLY (See figure 3-15.)
1 Place relief cap gasket (13) over flame arrestor (14) and seat it
i n s i d e r e l i e f c a p ( 1 2 ).
2 Install flame arrestor (14) on relief cap (12). Rotate flame arrestor
right until two pieces are joined tightly together.
3 Place flame arrestor (14) into vent pipe (11) until vent pipe contacts
r e l i e f c a p ( 1 2 ).
Rotate relief cap to right until vent pipe and relief
cap are joined tightly together.
3-17. MAINTENANCE OF FILLER/DISCHARGE ASSEMBLY.
T h i s t a s k c o v e r s : a.
D i s a s s e m b l y b . S e r v i c e c . A s s e m b ly
General Mechanics Automotive Tool Kit, SC 5180-90-CL-N26
Torque wrench (ft-lb), item 3, appendix B
Torque wrench (in-lb), item 2, appendix B
Cleaning solvent, item 1, appendix E
Detergent, item 4, appendix E
Rags, item 6, appendix E
Silicone compound, item 7, appendix E
3-34
INITAL SETUP
Tools
Materials/Parts
|